PRODUCTS

Details >> |
Multi
purpose plant for for regeneration and decolorizatrion of
mineral oil (motor, transmission, hydraulic and others)
purification, decolorization and sulfur elimination from diesel,
stove and other fuels, pirolysis liquid decolorization and odour
removal
Motor mineral oil
regeneration plant Details >> |
|

Details >> |
URM-0.7
OIL RECLAMATION
SYSTEM
This system is designed for reclamation
(restoration to
operational condition)
of electric insulation oils
with viscosity up to 70cSt
at 50 degrees Centigrade.
The system lowers acid number and dielectric loss
tangent by over 90%.
The oil reclamation system
allows lightening and purification of oil with application of
bleaching earth.
The
unit can be used during installation,
repairs and operation
of oil-filled
high voltage equipment up to 1150kW
(power transformers,
high voltage switches,
etc).
Operating
ambient conditions for the URM-0.7
system:
-
ambient temperature range +10ºС
… +35ºС;
-
atmospheric pressure
84
to 106,7
kPa
(24.80 to 31.49 in. hg.);
-
elevation up to
2000 м
(6562 feet) above sea level
-
explosion and fire proof
building.
Details >> |
|

Details >> |
UVM-6 TRANSFORMER OIL PROCESSING SYSTEM
UVM-6 system is designed for degassing, solid
particle removal, nitrogenation and heating of transformer oil,
filled into power transformers up to 1150 kW.
The oil processing station can be used for heating of oil filled
electric equipment with hot transformer oil, as well as for
vacuumizing power transformers.
The UVM-6
can be used for installation,
repair and operation of
power equipment.
Application of the unit in closed rooms required
exhaust ventilation.
Details >> |
|

Details >> |
UVM-10M TRANSFORMER OIL PROCESSING SYSTEM
UVM-10M
system is designed for degassing, solid particle removal,
nitrogenation and heating of transformer oil, filled into power
transformers up to 1150 kW.
UVM-10M
oil purification system consists of two primary components:
oil section (OS) and
vacuum section (VS).
The oil processing station can be used for
heating of oil filled electric equipment with hot transformer
oil, as well as for vacuumizing power transformers.
The UVM-10M
can be used for installation,
repair and operation of
power equipment.
Application of the unit in closed rooms required exhaust
ventilation.
Details >> |
|

Details >> |
UVM-10-10 TRANSFORMER OIL PROCESSING SYSTEM
UVM-10M
system is designed for degassing, solid particle removal,
nitrogenation and heating of transformer oil, filled into power
transformers up to 1150 kW
The
oil processing station can be used for heating of oil filled
electric equipment with hot transformer oil, as well as for
vacuumizing power transformers.
The UVM-10-10
can be used for installation,
repair and operation of
power equipment.
This system is containerized,
with lockable
door.
The UVM-10-10
cannot be operated in
explosive,
toxic or chemically aggressive
environments Application of the unit in closed rooms required
exhaust ventilation.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-1.7Z
Oil purification system SMM-1.7Z is designed for
removal of solids and water from lubrication and insulation oils
with viscosity less than 70 cSt at 50 degrees Centigrade,
with zeolite absorbent and for subsequent
regeneration of zeolite directly in the unit.
The
unit is used for installation,
repairs and operation
of oil filled high voltage equipment with voltages up to
500 kV (power
transformers, high voltage switches etc). Ambient conditions for
operation:
-
ambient temperature
+ 10
to + 35degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-3.5Z
Oil purification system SMM-3.5Z is designed for
removal of solids and water from lubrication and insulation oils
with viscosity less than 70 cSt at 50 degrees Centigrade,
with zeolite absorbent and for subsequent regeneration of
zeolite directly in the unit.
The
unit is used for installation,
repairs and operation
of oil filled high voltage equipment with voltages up to
500 kV (power
transformers, high voltage switches etc). Ambient conditions for
operation:
-
ambient temperature
+ 10
to + 35degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-5Z
Oil purification system SMM-3.5Z is designed for
removal of solids and water from lubrication and insulation oils
with viscosity less than 70 cSt at 50 degrees Centigrade,
with zeolite absorbent and for subsequent regeneration of
zeolite directly in the unit.
The
unit is used for installation,
repairs and operation
of oil filled high voltage equipment with voltages up to
500 kV (power
transformers, high voltage switches etc). Ambient conditions for
operation:
-
ambient temperature
+ 10
to + 35degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
MOBILE OIL PURIFICATION ZEOLITE SYSTEM MZU-1,7
The oil purification system MZU-1.7
is designed to remove
solids and water and to redice acidity of electric insulation
oils with viscosity of no more than
70 cSt at
50ºС.
Invertable sorbent cartridges ZP-260
are designed to purify
and dry transformer oil with zeolite absorbent.
The
system is used for installation,
repair and operation of
oil filled equipment with up to
1150 kV voltage
(power transformers,
high voltage switches
etc).
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building
The system consists of two independent units,
BNF for heating and
filtration and ZP-260 (zeolite
absorber), which are connected by flexible hoses.
Details >> |
|

Details >> |
ZEOLITE DRYING CABINET ZDC-15
Zeolite drying cabinet,
also referred to as
drying cabinet, is designed to remove moisture from zeolite.
This unit is a must for facilities that use absorbent for deep
dehydration of transformer oils. Other applications include
dying of welding electrodes.
Ambient
conditions for operation:
-
ambient temperature
+ 10
to + 35degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
The unit is mounted on a frame of profiled metal and steel
sheets. The frame supports drying chamber and two side chambers,
where electric heating rods are installed. A fan, which supplies
air from the chamber to the heaters and than back to the chamber
through opernings in its sides, is located on the back side of
the frame. Upper part of the drying chamber is equipped with two
manufolds and the lower part has a manifold with slide valve.
The frame is thermally insulated to reduce heat losses.
Control panel is mounted on a well next to the cabinet and
allows for easy adjustment of the zeolite drying process.
Details >> |
|

Details >> |
ZEOLITE RECLAMATION SYSTEM BRZ-100
Zeolite reclamation system BRZ is designed for
restoration of operational specifications of zeolite in ZP-260
cartridges.
This system can be applied by energy generation, industrial and
other facilities which use ZP-260 sorbent cartridges for
dehydration of transformer and lubrication oils.
The system comprizes the following major
components:
-
air heater;
-
air blower;
-
air cooler;
-
vacuum pump;
-
control system;
-
base frame with tilt wheels;
-
technical components,
interconnected with flexible hoses;
-
exhaust device.
Details >> |
|

Details >> |
AIR DRYING SYSTEM "SUKHOWAY-4"
Suhoway-4
air drying system is designed
for dehydration and solid removal from air,
used for blowing of
power transformer tanks and other electric equipment during
instllation,
maintenance and repair
operations to protect electric insulation from moisture when the
active core is open to outside environment.
The system operaties as two cyclic adsorbers,
filled with synthetic
zeolite for drying and a filter for removal of dust from the air.
The system is a metal container,
divided into two
compartments,
with a muffler on the input
connector and air distribution device on the outflow connector,
with disk gates. The air distributor has a pressure gauge and
condensate drain valve.
Upper part of the container is divided into two sections. One
section contains adsorbers with air heaters. The absorbers are
filled with sysmthetic zeolite and insulated with slagwool. The
adsorbers are connected with an air duct. The other section
contains control cabinet and dry air outflow connector.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-2,2S
Oil purification system SMM-2.2S is designed to
purify petrochemical fluids (oils, hydrolic fluids, diesel fuel)
from solid contaminants with density higher than that for the
fluid purified, and water. Viscosity of the fluid must not
exceed 300 cSt at 20ºС.
If the viscosity of the fluid is 300 cSt, capacity of the system
will not exceed 0,6
m3/hour.
The system ensures required degree of fluid
purity for manufacturing,
maintenance and repair of
various energy related equipment,
road construction heavy
duty machines,
motors,
manufacturing equipment
etc to improve reliability and extend life time of hydro-oil
assemblies.
The system can operate in two modes. The first
mode is to accumulate solid contaminants and water on centrifuge
hull, (with drain of low-adhesion water and contaminants to
container during pauses in operation).
The second mode is to drain the accumulated water from the
centrifuge continuously. Mode of operation is chosen depending
on the amount of water and solid contaminants in the liquids and
on the duration of the system’s continuous operation.
THIS SYSTEM CANNOT BE USED TO PURIFY FLAMMABLE
LIQUIDS WITH FLASHPOINT LESS THAN 65ºС,
as well as toxic
liquids and liquids aggressive to aluminum alloys,
non-corrosion
resistant steels and oil-resistant
rubber.
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-0.16
SMM-0.16
oil
purifiation system is designed for removal
of solids and and thermo-vacuum
removal of water and gases from lubricant and electric
insulation oils with viscosity of no more than
70 cSt
at 50С.
The oil purification system is used for maintnenace,
repair and operation of oil-filled
high-voltage
equipment with voltage up to 1150
kV
(power transformers,
high voltage switches
etc).
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-1
Oil purification system SMM-1
is designed for removal
of solid particles,
water and gases from electric
insulation oils with viscosity up to
70 cSt at
50ºС.
The system purifies oil to class
9 purity with source
purity class 13 (impurities
by weight no more than 0,004%)
after multiple passes
of the product through filter block.
The oil purification system can be used for
installation,
repair and operation of oil
filled high-voltage
equipment up to 1150
kV
(power transformers,
high voltage switches
etc).
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35 degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-1.7A
Oil purification system SMM-1.7A
is designed for removal of solid particles,
water and gases from
electric insulation oils with viscosity up to
70 cSt at
50ºС.
The system purifies oil to class
9 purity with source
purity class 13 (impurities
by weight no more than 0,004%)
after multiple passes
of the product through filter block.
The oil purification system can be used for
installation,
repair and operation of oil
filled high-voltage
equipment up to 1150
kV
(power transformers,
high voltage switches
etc).
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35 degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-2,2
Oil purification system SMM-1.7A
is designed for removal of solid particles,
water and gases from
electric insulation oils with viscosity up to
70 cSt at
50ºС.
The
system is comprised of oil pumps,
retainer and fine
filters,
vacuum tank,
vacuum pump,
control cabinet,
piping system.
The control cabinet contains circuitry for control of the system
operation. Control circuit is protected by automatic switch.
The front panel of the control cabinet contains
light indication of pump and heater operation.
Oil enters the system via the mesh filter,
oil gear pump,
and retainer to the
vacuum tank jacket,
where it ie heated to
+55 / 60 degrees Centigrade
by electric heaters.
The oil then passes
into the vacuum tank, where moisture from the oil is evaporated.
Water vapor and gases are removed nu the vacuum pump, and the
dehydrated oil passes through fine filter. All gear pumps are
equipped with safety valves.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-4A
Oil purification system SMM-4A is designed for
removal of solids, gas and water from electric insulation oils
with viscosity up to 70 cSt at 50ºС.
The
system purifies oil to class 9
purity with source
purity class 13 (impurities
by weight no more than 0,004%)
after multiple passes
of the product through filter block.
The oil purification system can be used for
installation,
repair and operation of oil
filled high-voltage
equipment up to 1150
kV
(power transformers,
high voltage switches
etc).
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35 degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
MOBILE OIL PURIFICATION SYSTEM SMM-0,6F
The SMM-F type systems are designed for
purification of diesel fuel, transformer, turbine, hydraulic and
industrial oils from solids, cinder, solved and partially free
water, water-soluble acids and bases.
The system is equipped with filters,
which absorb up to
98% of water and
improve purily class
of the oil.
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35 degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
MOBILE OIL PURIFICATION SYSTEM SMM-4F
The SMM-F type systems are designed for
purification of diesel fuel, transformer, turbine, hydraulic and
industrial oils from solids, cinder, solved and partially free
water, water-soluble acids and bases.
The system is equipped with filters,
which absorb up to
98% of water and
improve purily class
of the oil
The SMM-4F
system is designed for removal of solids,
cinder,
free and solved water,
water-soluble
acids and bases from oils.
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35 degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-0,5A
The SMM-0.5A
oil purification system is designed for removal of solids and
water from transformer,
turbine,
hydraulic,
industrial and other
oils.
The system is used for installation,
repair and operation of
oil-filled
equipment.
Ambient
conditions for operation:
-
ambient temperature
+ 10
to + 35 degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-0.6R
The SMM-0.6R oil purification system is designed
for removal of solids, gases and water from electric insulation
oils with viscosity up to 70 cSt at
50 degrees Centigrade.
The unit privides for purification to class
9 purilty with incoming
purity class 13 (impurities
by weight no more than 0.004%)
after multiple passes
of the product through filter assembly.
The oil purification system can be used for
installation,
repair and operation of oil
filled high-voltage
equipment up to 1150
kV
(power transformers,
high voltage switches
etc).
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35 degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-0.6V
The SMM-0.6V oil purification system is designed
for removal of solids and thermovaccum removal of water and ases
from lubricating and electric insuation oils, with viscosity up
to 70 cSt.
This system is explosion proof.
Explosion protection class
Exd II Ct4.
Principles
of opeation in filtration and thermovacuum purification mode.
The oil enters the unit via the unput pump, mesh
filer and filter cartridge and goes to vacuum tank sprayer.
Vacuum in the tank is maintained by the vacuum pump and is
controlled with the vacuum pressure gauge.
Purified air,
entering the tank,
removes vapor and
gasesfrom the surface of the oil
drying it. Moinst air
is discharged by the vacuum pipe into the atmosphere,
after passing through
oil separator filter.
Purified oil is then directed to clean oil tank.
Operation in degassing mode.
The oil for processing enters the vacuum tank’s
spraye via the pump,
mesh filter and cartridge
filtter. After that the oil goes into the vacuum tankм.
Gases separate from the oil in the sprayer The
gases are discharged into the atmosphere. The degassed oil runs
through fine filter and non retirn valve an oil output tank.
очистки и клапан обратный в ёмкость
чистого масла.
Details >> |
|

Details >> |
OIL PURIFICATION SYSTEM SMM-4V
The SMM-4V oil purification system is designed
for removal of solids and thermovaccum removal of water and ases
from lubricating and electric insuation oils, with viscosity up
to 70 cSt.
This system is explosion proof.
Explosion protection class
Exd II Ct4.
Principles
of opeation in filtration and thermovacuum purification mode.
The oil enters the unit via the unput pump, mesh
filer and filter cartridge and goes to vacuum tank sprayer.
Vacuum in the tank is maintained by the vacuum pump and is
controlled with the vacuum pressure gauge.
Purified air,
entering the tank,
removes vapor and
gasesfrom the surface of the oil
drying it. Moinst air
is discharged by the vacuum pipe into the atmosphere,
after passing through
oil separator filter.
Purified oil is then directed to clean oil tank.
Operation in degassing mode.
The oil for processing enters the vacuum tank’s
spraye via the pump,
mesh filter and cartridge
filtter. After that the oil goes into the vacuum tankм.
Gases separate from the oil in the sprayer The
gases are discharged into the atmosphere. The degassed oil runs
through fine filter and non retirn valve an oil output tank.
очистки и клапан обратный в ёмкость
чистого масла.
Details >> |
|

Details >> |
STREAM OIL HEATER PPM SERIES
PPM series stream oil heaters are designed for heating of
transformer oils for filling, replacement or drying of
transformers. They can also be used for mineral, industrial,
turbine and other oils, as well as other liquids which do not
cause corrosion of the contruction materials of these heaters.
The heaters can be used for repair and maintnence of transformers,
at power stations and
for other oil related applications. The heaters can be operated
both indoors and outdoors under sufficient cover.
The heater consists of a welded frame with two
heating tanks inside. Each tank is equipped with a tubular
grate, on which 12 tubular electric heaters at 3 kW each are
mounted. Heater terminals are protected by jacket.
Inegrated conrol unit is mounted on the tanks.
The heater is equipped with input valve, mesh filter, air and
oil discharge vlaves and two thermo-resistors.
Details >> |
|

Details >> |
STREAM HEATER PPM-600
Stream liquid heater is designed for heating of
oil and other liquids with kinetic viscosity less than
70 mm2/s
at 50ºС,
which do not cause corrosion of heater
construction materials,
in temperature range from
+20˚С to
+90˚С.
The heater can be used for heating of oil for oil-filled
equipment,
as well as for heating
petrochemical products in petrochemical technology processes.
The heater is explosion protected to Exd II CT4.
The heater consists of a frame with three heating
section, each section includes: jacketed-pipe heat exchangers,
heater, pump, extension tank, control panel, piping with
corresponding valves and regulators, input and output
collectors. Process parameters are controlled by:
temperature regulators,
2TRM
“Oven”
with TSM type sensors,
pressure gauges and
thermometers for visual
temperature control.
Details >> |
|

Details >> |
OIL FILTRATION SYSTEMS ZFU-1.7,
ZFU-0.8
The ZFU
series oil filtration systems are designed for removal of solids
from lubricant and electric insulation oils with viscosity up to
70 cSt
at 50ºС,
and for purification of diesel fuel. These units
can be used for installation, repair and operation of oil-filled
equipment.
The unit ensures purification to class
10 purity with initial
class 14
purity (
contaminant content not more
than 0,008%)
in multimple passes of the
purified product through the filters.
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35 degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
Details >> |
|

Details >> |
FILTRATION SYSTEM BF-10
The BF-10
filtration system is designed
for removal of solid contaminants from all types of mineral oils
with temperature less than +50ºС
and viscosity less than
70
cSt.
The unit ensures purification to class
10 purity with initial
class 14
purity (
contaminant content not more
than 0,008%)
in multimple passes of the
purified product through the filters.
This system is applicable for installation,
maintenance and
opewration of oil-filled
equipment.
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35 degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
-
elevation up to
2000 m;
-
fire and explosion proof
building.
The filtration system consists of:
-
section
1, including
2 cartridge filters,
2 pressure gauges and
piping;
-
section
2, including 2
cartridge filters,
2 pressure gauges and
piping.
Details >> |

Details >> |
SPRAYING SYSTEM UR-0.8
Spraying unit UR-0.8
is designed for
spraying of oils and other non-toxic
liquids on the surfaces of forms for manufacturing of concrete
structures,
as well as other process
applications.
The unit can be used by small and mid-size
concrete production facilities, as well as larger factories at
construction material production lines.
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35 degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
The unit’s main component is a plastic 30 liter tanks. Oil is
filled through the unput opening and 1 mm mesh filter. Oil is
taken for spraying through manifold in the tank. To prevent
suction of sediment at the bottom of the tank, the manifold is
raised 20 mm from the bottom. A cover, only removed for oil
filling, protects the tank from foreign objects.
Details >> |

Details >> |
VACUUM OIL FILLING SYSTEM UVD-4M
The vacuum oil filling system is designed for
preparation (degassing),
storage,
transportation and
injection of transformer oil into the high-voltage
ports of transformers and switches and can be used at power
plants,
power distribution stations and other energy
related facilities.
Ambient conditions for operation:
-
ambient temperature
+ 10
to + 35 degrees
Centigrade;
-
atmospheric pressure
84
to 106,7
kPa
(26.77 to 31.49 in.hg);
The UVD-4M system consists of:
-
degassing section;
-
injection section;
-
vacuum pump;
-
control panel.
The degassing section is an airtight cylindrical
vessel,
with airtight oil input opening, two ball valves
and vacuum pressure gauge. (-1…0 kg/cm²).
The valve is connected to the vacuum pump via collet fitting,
flexible hose and a valve. The valve is equipped with a muffler.
Injection section is a pneumatic cylinder with
piston diameter of 160 mm. The section will take oil from the
degassing section and inject it into the transformer’s port. The
piston is manually driven by a screw pair. Oil distribution
assembly is fitted into the lower part of the cylinder, which
consists of pipeline, ball valve and vacuum pressure gauge
(-1…0…9
kg/cm²).
Vacuum pump (sliding
vane rotary pump,
mod
50810-235)
is designed to create vacuum in the degassing
section.
The pump is driven by one phase
220 V power supply.
Details >> |
|
|